The new E7+ from Secure is the latest version of the Electronic 7 hot water programmer. Designed to be the successor to both the Electronic 7 and the Economy 7 Quartz, it is easy to install or retrofit. Now with a new compact interface that is perfect for newer installations, as well as an adaptor plate to make retrofitting a simple matter of plug and play. The E7+ can be controlled by the Secure Bluetooth-enabled App, within a property, and there is even an optional plugin Wi-Fi card that will turn the E7+ into a truly smart unit you can control from anywhere. E7+ is designed to control one or two 3kW immersion heaters, can also be programmed locally to provide a full tank of hot water whenever required during off-peak electricity timing. Each heater can be programmed separately for maximum energy saving and control. The E7+ is perfect for standalone control of electric hot water and uses the same app as our range of smart-capable programmable thermostats - C1727 and H3747.
Electrical | |
Contact rating | 13 Amps 230V AC Suitable for immersion heaters up to 3kw |
Contact type | Micro-disconnection on control, disconnection to immersion heaters on double-pole rocker switch |
Supply | 230V 50Hz |
Environmental | |
Pollution degree | Degree 2 normal situations |
Moisture protection | Ordinary |
Enclosure protection | IP30 |
Features | |
Shock protection | Class 1 |
Live parts | Enclosed |
Operating temperature range | 0°c to 35°C |
Battery reserve | Approximately 2 years total power disconnection |
Clock | am/pm Indication Winter/Summer indication |
Programme options | Full 7-day programmming; Off-peak & Boost, up to three time periods each; Boost – programmable automatic boost and 1/2, 1, and 2-hour manual boosts |
Mechanical | |
Dimensions | 170 x 115 x 60mm (excluding rocker switch) |
Radio | |
Compliance | Bluetooth BLE compliant |
Operating frequency | 2.4 GHZ |
RF range | ~60m, line of sight |
Compliance | |
Product Standard/Safety : BSEN / EN 60730-1, BSEN / EN 60730-2-7 RED Radio: ETSI EN 300 328 RED EMC: ETSI EN 301 489-1, ETSI EN 301 489-17, BS EN 60730-2-7 |